Tel: 86-577-67302790 67398303
Email: JIUKANG@JIUKANG.COM
PRODUCTS
JK-M15-2a
    Publish time 2018-06-25 15:05    

Performance And Characteristics

Simple construction, reliable performance

The product can output stable and reliable switch control signal of "making", "breaking" without any fault action, so its eliability is very high and antinter-ference is strong.


Sturdy and durable, need not maintain

The product can be used for a long time after it being installed. Almostno maintenance and repairing problem would occur during its operation period.


Easy installation method, convenient adjustment method

The liquid level control scope can be adjusted at will with the locating piece moving up and down. Only one screw is needed to secure the signal cableto finish installation.


Wide application scope, strong generalityWide application scope, strong generalityWide application scope, strong generality

The product applies to branch water, sewage acid-base solution of less than medium concentration, oils and situations requiring no pollution (for example food and drinks industry), diesel oil gasification kitchen range, and automatic fuel feeding.


     

Simple circuit. economial and practical

Operation voltage is 200V, and current can be up to 10A, The applied circuit of the product is simple, so application costis very low.


Instructions for installation

May be used for direct level contor1. In accordance with product electrical specifications. In the case of approved products, the ground wire will always be included and the ground wire sheath will always be yellow/green. In this case, this two remaining wires are supplied for "high closure" or, specific request, "low closure".




Installation of counterweight

Use wires:                                        Use wires:

"Black" and "Blue"                           "Black" and "Blue"

with these contacts the regulator     with these contacts the regulator

Closes when down                           Closes when up

Opens when. up                               Opens when down.

The wire that is not used must be

correctly insulated


The product can be used for a long time after it being installedThe product can be used for a long time after it bei

Performance and characteristics

1. Insert the cable in the counterweight. From the conical part and rotate it. Thus causing the plastic ring inserted in the opening to become detached (if necessary this operation can be facilitated with the use of a screwdriver). The ring should then be positioned in the point where it is desired to block the counterweight.

2. Force the counterweight on the ring by rotating it, using a slight pressure.



The counterweight is furnished only on request.
Avoid joints in the levelregulator cable. never immerge possible cable joints in the water.