Tel: 86-577-67302790 67398303
Email: JIUKANG@JIUKANG.COM
PRODUCTS
CBB60-3A
    Publish time 2018-07-13 15:56    

 

Capacity

Dimmension

( μ f )

D*H (mm)

1

30*57

1.5

2

3

4

5

6

7

8

35*60

9

10

12

40*70

14

16

18

20

40*95

25

30

35

45*95

40

45

50*106

50

55

60

50*116

65

70

75

55*120

80

85

90

60*120

95

100

 



Applications
JK series motor run capacitor has features of small size, light weight, small tangent in waste angle, and good self-healing. Applicable to start and operation with 50/60Hz A. C. Single motor, specially suit for micro pump, baric pump, micro motor and so on.


Service Conditions

1. Altitude: the altitude of area of installation and operation not exceeding 2000m.
2. Residual voltage at energization: Not to exceed 10% rated voltage.
3. Pollution: No electric dust, no corrosive as or inflammable and explosive medium in the area of installation and operation.
4. Operation temperature : -40°C~+7℃.
5. Operation way: Continuous operation.


Manufacturing
Self-healing metallized polypropylene film capacitors. Non inductive winding.
Wound capacitor elements fully immersed into resin. Self-extinguishing plastic case.
Extinguishing plastic case.
Executions:
Flat bottom-metal fixing stud M8x12
faston terminals 0.8x6.35 simple or double
standard distance P=13.2mm ±0.5
uniplar cable-bipplar cable
discharge resistance-plastic cover


Main Technical Indexes

1. Range voltage: 200VAC, 250VAC, 400VAC, 450VAC, 500VAC.
2. Rated frequency: 50Hz(60Hz).
3. Rated capacitance: 1.0 μ F-60 μ F.
4. Withstand AC voltage between terminals: 1.75 times than rated voltage for 2 seconds.
5. Withstand AC voltage between terminal and case: 2000VAC for 2 seconds.
6. Capacitance tolerance: Cn ± 5%.
7. Tangent of loss angle(tg δ ): tg δ ≤ 0.10%(50Hz).
8. Maximum permissible voltage : 110% rated voltage.
9. Maximum permissible current: 130% rated current.
10. Class of safety protection: P0(type CBB60, CBB61), P1(type CBB65).
11. Design service life: 3,000 hours (class C).
12. Standard: in conformity with GB3667-1997,IEC60252-1993.